Thermal resistance

Junction temperature and the heatsink you need.

Junction temperature–
Heatsink needed
–
Without a heatsink (θJA)
–

How it works

Heat flows through a chain of thermal resistances: Tj = Ta + P × (θJC + θCS + θSA). Without a heatsink, Tj = Ta + P × θJA.

The heatsink you need: θSA = (Tj max − Ta) / P − θJC − θCS. Leave some margin.