Voltage regulator

Linear regulator heat and efficiency; LM317 resistors.

Heat in the regulator–
Efficiency
–
Headroom (Vin − Vout)
–
Junction temperature
–
A switching regulator instead
–
Output voltage–
R2 for the voltage you want
–

How it works

A linear regulator turns the extra voltage into heat: P = (Vin − Vout) × I + Vin × Iq. Junction temperature = ambient + P × θJA; keep it below the datasheet limit (often 125 °C).

LM317: Vout = 1.25 V × (1 + R2/R1) + 50 µA × R2. R1 of 240 Ω keeps the minimum load current flowing.